Cappa Chimica di Laboratorio YR05808 / YR05812
Acciaio epossidico · resistente ad acidi e alcali · ≤ 60 dB

Le Kalstein YR05808 e YR05812 sono cappe chimiche di laboratorio in acciaio laminato a freddo 1,2 mm con rivestimento epossidico resistente ad acidi e alcali forti. Piano in resina fenolica, vetro temperato e soffiante assiale 0,4-0,6 m/s proteggono l'operatore con rumore inferiore a 60 dB.
Interactive tour
Every component, engineered for your safety
Click the hotspots to explore the materials and systems that make this hood a reliable choice for basic chemistry.
Componenti ispezionabili
- Epoxy-coated steel bodyStructure
Cold-rolled steel body with epoxy powder coating for chemical resistance.
- Tempered glass windowSafety
Transparent front barrier protects the operator while preserving visibility.
- Axial blowerExtraction
Adjustable blower captures vapors through the front opening.
- Upper exhaust ductAirflow
Captured fumes leave through the top duct toward extraction or exterior exhaust.
- Phenolic resin worktopMaterials
Durable 12.7 mm work surface for routine chemical handling.
- LED lightingLighting
Integrated lighting keeps reactions and glassware clearly visible.
Caratteristiche principali
- Corpo in acciaio 1,2 mm con rivestimento epossidico
- Velocità frontale 0,4-0,6 m/s in tre modalità
- Estrazione 800-1000 m³/h · soffiante assiale · condotto superiore
- Piano in resina fenolica 12,7 mm
- Vetro temperato con contrappeso
- Illuminazione LED 10 W ≥ 800 lux · rumore ≤ 60 dB
Tripla protezione · strati ingegnerizzati
Operator protection
Front sash and horizontal room-air intake keep vapors and fumes inside the chamber and away from the operator.
- Front sash
- Room-air intake
- Alarm on low flow
- Face velocity
- 0.5 m/s
- Noise level
- ≤ 60 dB
- LED lighting
- 10 W
Structural durability
Cold-rolled steel with epoxy coating resists chemical spills and years of daily operation.
- Epoxy coating
- Phenolic worktop
- Tempered glass
- Steel gauge
- 1.2 mm
- Worktop
- 12.7 mm
- Tempered glass
- 5 mm
Versatile installation
Available in two widths and compatible with laboratory exhaust ducts up to 3 m.
- 1300 mm width
- 1800 mm width
- Top duct output
- m³/h airflow
- 800–1000
- Duct length
- 3 m
- Power
- 220 V
Modalità di flusso · cosa accade in ogni direzione
- Low — Low airflow · 0.4 m/s
Recommended for low-volatility solvents and general handling.
- Medium — Medium airflow · 0.5 m/s
Optimal balance for most chemistry protocols.
- High — High airflow · 0.6 m/s
Aggressive extraction for highly volatile or toxic vapors.
- Auto — Automatic purge cycle
Periodic full-power ventilation to purge residual vapors before shutdown.
Specifiche tecniche
| Modello | YR05808 / YR05812 |
|---|---|
| Costruzione | Cold-rolled steel 1.2 mm · epoxy powder coating |
| Velocità frontale | 0.4 – 0.6 m/s |
| Portata di estrazione | 800 – 1000 m³/h |
| Livello di rumore | ≤ 60 dB |
| Illuminazione | LED 10 W |
| Piano di lavoro | Phenolic resin 12.7 mm |
| Vetro frontale | Tempered safety glass |
| Dimensioni esterne | YR05808: 1300×850×2350 · YR05812: 1800×850×2350 mm |
| Alimentazione | 220 V / 50-60 Hz |
Applicazioni
- Didattica chimica
- Controllo qualità
- Preparazione con acidi/basi
- Chimica industriale e alimentare
- Ricerca con solventi volatili
Casi d’uso reali · flussi guidati
General chemistry laboratory
Everyday handling of solvents, acids and bases in teaching and research chemistry.
- Open sash to working height
- Turn on fan and lighting
- Perform reactions inside the chamber
- Close containers and lower sash
- Purge before shutdown
Pharmaceutical compounding
Weighing and mixing of raw materials in compounding pharmacies.
- Clean worktop and calibrate balance
- Introduce ingredients
- Weigh and mix inside the chamber
- Package and label
- Clean the fume hood
Analytical sample preparation
Sample digestion, extraction and preparation for chromatography or spectroscopy.
- Prepare glassware
- Add solvents inside the hood
- Perform digestion or extraction
- Transfer sample to instrument
- Decontaminate
Fast quotation · 15 seconds
Add the YR05808 to your chemistry lab
Two widths, one quality standard. Receive full specification, delivery and installation in a single quote.
Domande frequenti
Per quali sostanze chimiche?
Chimica di base con acidi e alcali forti. Per perclorico/fluoridrico usare YR05820-SS inox.
Differenza YR05808/YR05812?
1300 mm vs 1800 mm larghezza, stessa costruzione.
Serve condotto esterno?
Sì, cappa canalizzata da collegare all'estrazione sul tetto.
Rumore?
≤ 60 dB in postazione operatore a massima velocità.