Doppler Fetal Monitor YR02180

SKU:YR02180 · Di Kalstein

Categoria:Patient and fetal Monitor

Doppler Fetal Monitor YR02180

Il Doppler Fetal Monitor YR02180 è un dispositivo di monitoraggio paziente altamente versatile e avanzato, ideale per l'uso nei cinema operativi (OT) e nelle un

The Doppler Fetal Monitor YR02180 is a highly versatile and advanced patient monitoring device, ideal for use in operating theatres (OT) and intensive care units (ICU). With a 17-inch LCD screen and semi-modular parameters, this monitor provides comprehensive monitoring with six standard parameters, including ECG, SpO2, TEMP, NIBP, RESP, and PR/HR. This device offers optional features like a touch screen, extended ECG leads, and various mounting solutions, making it adaptable for different clinical settings and requirements.

Market Price

The price range for the Doppler Fetal Monitor YR02180 in the market generally falls between $3,500 and $4,200, depending on the specific configuration and optional features selected. This competitive pricing reflects the device's advanced capabilities and robust design, making it a smart investment for healthcare facilities looking to enhance their patient care services.

Frequently Asked Questions

What are the standard parameters included with the monitor? The monitor comes with six standard parameters: ECG, SpO2, TEMP, NIBP, RESP, and PR/HR.

Can the monitor be configured for different clinical settings? Yes, it offers a range of optional features such as a touch screen, additional ECG leads, and mounting options to suit various clinical environments.

Advantages and Disadvantages

Advantages: The Doppler Fetal Monitor YR02180 is versatile and can be customized per the clinical need, making it suitable for multiple patient monitoring scenarios. Its comprehensive parameter set ensures thorough patient data capture.

Disadvantages: The initial setup and configuration might require some technical know-how, and accessing certain optional features could incur additional costs.

Field Use

In practical terms, the Doppler Fetal Monitor YR02180 is well-suited for critical care environments such as ICUs, where continuous and accurate patient monitoring is essential. The device's semi-modular nature allows for easy adaptation to different clinical needs, ensuring that healthcare professionals can rely on it for diverse patient monitoring requirements.

Recommendations

To maximize the functionality of the Doppler Fetal Monitor YR02180, ensure regular calibration and maintenance as per the manufacturer's guidelines. It's also advisable to familiarize healthcare staff with the device through training sessions to fully utilize its capabilities.

Features

  • 17-inch LCD screen with semi-modular configuration
  • Standard parameters: ECG, SpO2, TEMP, NIBP, RESP, PR/HR
  • Optional features: Touch screen, extended ECG leads, mounting solutions
  • Designed for use in OT and ICU environments

Technical Specifications

ModelYR02180
ECG
Lead mode5 Leads(RA,LA,LL,RL,V)
Connection methodI, II, III,AVR,AVL,AVF,V
Lead Mode3 Leads (RA,LA,LL)
Connection methodI, II,III
Gainx250, x500, x1000, x2000
Accuracy±5%
Resolution1bpm
Sensitivity>200(uVp-p)
Differential input impedance≥5MΩ
ST segment Monitoring Range
Measure Range-1.0~+1.0mV
Measure Accuracy-0.8mV~+0.8mV
Heart Rate
Measuring range40~240bpm
Accuracy±3bpm
Resolution1bpm
Sensitivity>200UVp-p
Respiration
MethodImpedance between R-F(RA-LL)
Measuring Impedance Range0.3~3.0 MΩ
Bandwidth0.1~2.5Hz
Respiration RateAdult: 7~120BrPM
Neo/Ped7~150BrPM
Resolution1 BrPM
Accuracy±2 BrPM
NIBP
MethodOscillometric
Measuring Interval in AUTO Mode1,2,3,4,5,10,15,30,60,90,120,180,240(Min)
Measuring Period in STAT Mode5 Min
Pulse Rate Range40~240bpm / 40~150bpm
Alarm TypeSYS, DIA, MEAN
Resolution
Pressure1mmHg
SPO2
DisplayNumber of SPO2,waveform of capacity,Pulse
Measuring range0~100%
Resolution1%
Accuracy70~99% (±2%)
Pulse rate range0~300bpm
TEMP
Channel2
Measuring and Alarm Range0~50ºC
Resolution0.1ºC
Accuracy0.1ºC
Actualization intervalabout 1 Second.
Average Time Constant<10 Second.

Specifiche tecniche

DimensioniL 57 × W 39 × H 53.5 cm
Peso8 kg
ProduttoreKalstein

Video Doppler Fetal Monitor YR02180

Domande frequenti

Come conoscere i prezzi di Doppler Fetal Monitor YR02180?

Per conoscere il prezzo di Doppler Fetal Monitor YR02180, inviaci un'email tramite il modulo di contatto AQUI.

Quali sono i tempi di consegna di Doppler Fetal Monitor YR02180?

I tempi dipendono dalla disponibilità a stock e dal tipo di spedizione (aerea o marittima). In stock: aerea 15-30 giorni, marittima 45-60 giorni. Non in stock: aerea 30-60 giorni, marittima 60-90 giorni.

Come effettuare un acquisto di Doppler Fetal Monitor YR02180?

Puoi acquistare via email ([email protected]), telefono (+33 (0) 1 70 39 26 50) o tramite il sito ufficiale Kalstein del tuo paese.

Come funziona la garanzia di Doppler Fetal Monitor YR02180?

Tutte le attrezzature Kalstein hanno una garanzia di 1 anno contro i difetti di fabbricazione. La garanzia non copre i danni da installazione o uso impropri. Vedi i nostri «termini e condizioni» AQUI.

Posso richiedere un preventivo online di Doppler Fetal Monitor YR02180?

Sì, puoi richiedere un preventivo direttamente dal nostro sito ufficiale. Clicca AQUI.