Description
The Doppler Fetal Monitor YR02180 is a versatile and essential tool for precise fetal monitoring in medical environments such as operating theaters and Intensive Care Units (ICUs). Equipped with a 17-inch LCD display, this semi-modular patient monitor includes six standard parameters: ECG, SPO2, TEMP, NIBP, RESP, and PR/HR. Optional features such as a touch screen, Masimo/Nellcor SpO2, and enhanced ECG configurations provide flexibility to adapt to varying medical needs. The well-structured design and comprehensive specifications make it an excellent choice for healthcare professionals seeking reliability and functionality.
Market Price
The Doppler Fetal Monitor YR02180 offers advanced features typically found in high-end monitors, positioning its market price within the range of $3,500 to $4,200. This competitive pricing reflects its technological sophistication and the comprehensive capabilities it provides for fetal monitoring, making it a worthwhile investment for healthcare facilities aiming to deliver top-quality care.
Frequently Asked Questions
- What is the primary use of the Doppler Fetal Monitor YR02180?
The primary use is for monitoring fetal heart rate and maternal parameters during pregnancy, labor, and delivery.
- Does it support wireless connectivity?
No, this model is designed for stationary use, and all parameters are monitored through cabled connections.
- Is training required to use this monitor?
While not mandatory, training is recommended to fully understand its functionalities and optimize its use within healthcare settings.
Advantages and Disadvantages
- Advantages: Comprehensive monitoring capabilities, optional customizations, robust design.
- Disadvantages: Lack of wireless functionality, learning curve for new users may be steep.
Product Use in the Field
The Doppler Fetal Monitor YR02180 is extensively used in hospitals and clinics for ongoing monitoring during labor. Its ability to track multiple vital signs provides healthcare professionals with real-time data essential for making informed decisions promptly. Its compatibility with various attachments and sensors further enhances its applicability in diverse clinical situations.
Recommendations
To maximize the effectiveness of the Doppler Fetal Monitor YR02180, regular calibration and maintenance checks are advised. Facilities should ensure that staff are adequately trained in its operation and take advantage of its modular capabilities to tailor it to specific needs. Detailed user manuals and support are available to facilitate seamless integration.
Features
- 17-inch clear LCD display
- Semi-Modular with six standard parameters
- Optional features for customization
- Comprehensive ECG measurements
- Robust and easy-to-use design
Technical Specifications
Model | YR02180 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Gain | x250, x500, x1000, x2000 | |
Accuracy | ±5% | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -1.0~+1.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 40~240bpm |
Accuracy | ±3bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 7~120BrPM | |
Neo/Ped | 7~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
NIBP
|
Method | Oscillometric |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm / 40~150bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~99% (±2%) | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second. | |
Average Time Constant | <10 Second. |