Description
The LCD Display Laboratory Autoclave Models YR06659 – YR06662 is a high-performance steam sterilization equipment specifically designed to guarantee biological safety in research and health environments. This device stands out for its versatility, allowing the processing of wrapped or unwrapped instruments, fabrics, and rubber items with superior efficiency. Its main purpose is to offer a traceable and secure sterilization cycle, facilitating the daily operation of laboratory professionals seeking cutting-edge technology and reliability in a single piece of equipment.
Diseño y Tecnología
This equipment integrates a microcomputer control system that intelligently automates and supervises each phase of the process.
-
LCD Interface: Large screen that allows real-time monitoring of critical parameters such as temperature and pressure.
-
Security Management: Three-level authority management system and memory storage to protect data in the event of electrical interruptions.
-
Steam Control: Six-stage steam exhaust system and integrated cooling fan to accelerate load availability.
-
Advanced Locking: Column-type safety device with internal electric double locking that prevents opening while pressure or high temperature exists.
Preguntas Frecuentes (FAQ)
-
What temperature range does it handle? The equipment operates in an adjustable range between 105°C and 138°C to adapt to different materials.
-
Can the sterilization time be programmed? Yes, it allows precise time adjustment from 1 to 300 minutes.
-
How does the equipment protect against water shortage? It includes a triple protection device that detects low levels and stops heating to prevent damage.
-
What self-diagnostic functions does it have? It features automatic fault detection and a steam exhaust verification system.
Ventajas y Desventajas (Pros y Cons)
Advantages:
-
Redundant Safety: Dual over-temperature alarms and independent pressure sensors for risk-free operation.
-
Thermal Efficiency: The cooling fan significantly reduces the waiting time between successive cycles.
-
Flexible Programming: Timed start function that allows organizing workflows in advance. Disadvantages:
-
Power Consumption: Higher capacity models operate at 4.0 kW, requiring a robust electrical installation.
-
Space Required: Its external dimensions of up to 1230 mm in height require a work area with adequate ventilation.
Uso en el Campo y Recomendaciones
This autoclave is ideal for microbiology laboratories, research centers, and clinics that process a high volume of samples and waste.
-
Recommendation: Use the waste sterilization mode specifically for contaminated materials to maximize biological safety.
-
Operation: It is suggested to adjust the exhaust speed according to the load to avoid damage to delicate materials or loss of liquids.
Especificaciones Técnicas
| Model | Chamber Dimensions (mm) | Sterilization Temperature (°C) | Sterilization (min) | Pressure | Manometer (MPa) | Power (kW) | Exterior Dimensions (mm) |
| YR06659 | 29L / φ325×380mm | 105-138 °C, design temp: 153 °C | 1-6000 minutes | Max working: 0.25 Mpa, Design: 0.3 Mpa | -0.1/0.5 Mpa | 2.3 | 460×542×1070 mm |
| YR06660 | 54L / φ325×670mm | 105-138 °C, design temp: 153 °C | 1-6000 minutes | Max working: 0.25 Mpa, Design: 0.3 Mpa | -0.1/0.5 Mpa | 4.0 | 460×542×1070 mm |
| YR06661 | 80L / φ400×709mm | 105-138 °C, design temp: 153 °C | 1-6000 minutes | Max working: 0.25 Mpa, Design: 0.3 Mpa | -0.1/0.5 Mpa | 4.0 | 620×680×1100 mm |
| YR06662 | 100L / φ400×809mm | 105-138 °C, design temp: 153 °C | 1-6000 minutes | Max working: 0.25 Mpa, Design: 0.3 Mpa | -0.1/0.5 Mpa | 4.0 | 620×680×1200 mm |