Description
The YR05475 Desktop Spectrophotometer is an advanced measurement tool developed by Kalstein, designed to perform highly precise color and appearance analyses across a variety of laboratory and research applications. This spectrophotometer stands out for its pulsed xenon lamp, which ensures a long service life and stability with each test. Equipped with a 7-inch TFT touchscreen and reflective d/8 and transmissive d/0 optical geometry (with or without UV component), the YR05475 allows reliable results on both solid and translucent or transparent liquid samples. Its dual-array 256-element CMOS sensor and automatic aperture identification system (Φ25.4 mm, 8 mm, and 4 mm) ensure high accuracy on any type of sample. Additionally, its storage capacity of up to 20,000 records and powerful PC software make it the ideal choice for R&D environments requiring consistent and detailed results.
Market Price
The YR05475 spectrophotometer is priced between $9,790 and $9,800 USD, making it a cost-effective and accessible investment compared to other high-end models on the market. This equipment is perfect for companies needing precise quality control in sectors such as plastics, paint, food, cosmetics, and medicine, where accuracy in color analysis is essential. To get a quote tailored to the specific needs of your industry, you can access the Kalstein Plus platform, where you can request a personalized, no-obligation quote with ease.
Frequently Asked Questions
- Is the YR05475 suitable for measuring both translucent and opaque samples?
Yes, this spectrophotometer is designed to analyze both opaque and translucent materials, including liquids and transparent solids. - What is the storage capacity of the YR05475?
This model allows storage of up to 20,000 results, facilitating extensive and detailed tracking of test data. - Is it possible to adjust the measurement aperture?
Yes, the YR05475 features three adjustable apertures (Φ25.4 mm, 8 mm, and 4 mm), offering flexibility in analyzing different sample types.
Advantages and Disadvantages
Among its multiple advantages, the YR05475 includes a temperature compensation system, ensuring accuracy even in variable environmental conditions. It also offers complete lighting options (LED and UV), and its ergonomic design facilitates prolonged use in demanding settings. However, a potential drawback is that this model may require periodic calibrations in high-use conditions to maintain optimal accuracy.
Field Use
This spectrophotometer is ideal for quality control and product development laboratories in high-demand industries such as automotive, cosmetics, medical, and food. Its ability to measure both reflectance and transmittance across a wide range of materials ensures that the YR05475 can optimize quality verification processes, maintaining high standards at every production stage.
Recommendations
To maximize the performance and durability of the YR05475, periodic calibrations and maintaining the device in a clean and stable environment are recommended. Adjusting the measurement aperture according to sample type and specific testing conditions will ensure greater accuracy and consistency in results. Request your personalized quote now through Kalstein Plus and discover how the YR05475 Desktop Spectrophotometer can transform your quality control and color analysis processes, providing precise and reliable measurements in every application.
Technical Specification
Model | YR05475 (Pulsed xenon lamp) |
Optical Geometry | Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) |
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003) | |
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |
Integrating Sphere Size | Φ 154mm |
Light Source Device | 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Pitch | 10nm |
Semiband Width | 5nm |
Reflectance Range | 0~200% |
Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
Specular Component | Reflectance: SCI&SCE |
Transmittance: SCI&SCE | |
Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) |
Observer Angle | 2° & 10° |
Illuminants | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%) |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%) | |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
(Average for 12 BCRA Series II color tiles) | |
Size | 370×300×200mm |
Weight | About 9.6kg |
Power Supply | DC 24V, 3A Power Adapter |
Light Source Device Life | 5 years, more than 3 million times measurements. |
Display | 7″ TFT Capacitive Screen-touch Display |
Data Port | USB & Print serial port |
Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English, |
Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, |
Optional Accessory | Micro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
Notes: The specifications are subject to change without notice. |