Description
The Bedside Monitor YR02174 is a highly versatile and essential tool for medical professionals seeking precision and reliability. Featuring a 15-inch display, this multi-parameter patient monitor comes with a standard configuration that includes SpO2, RESP, NIBP, PR/HR, ECG, and 2-TEMP. It also offers a variety of optional features such as 12 lead ECG, IBP, ETCO2, and more, ensuring it can meet the diverse needs of any healthcare setting. With its intuitive design, the YR02174 makes patient monitoring both efficient and highly accurate, making it an indispensable part of modern medical practices.
Market Price
The competitive landscape for bedside monitors sees a range of pricing due to varied features and specifications. Typically, products similar to the Bedside Monitor YR02174 can be found within the price range of 900 to 1800 USD. Given its extensive capabilities and advanced technology, this monitor is positioned within this price spectrum to offer both value and performance.
Frequently Asked Questions
Q: What kind of display does the YR02174 have?
A: It features a 15-inch display that ensures clear visibility of patient data.
Q: Can the monitor be wall-mounted?
A: Yes, the device offers wall mount options for flexible installation.
Q: Does it support pediatric use?
A: Yes, it is suitable for use with both adult and pediatric patients.
Advantages and Disadvantages
One of the main advantages of the Bedside Monitor YR02174 is its comprehensive multi-parameter capabilities, allowing for complete patient monitoring. The optional features make it adaptable to various clinical needs. However, the extensive range of options might present a slight learning curve for new users. Despite this, its benefits far outweigh any drawbacks, making it a valuable investment in patient care.
Product Use in the Field
In clinical environments, the YR02174 enhances patient care by delivering real-time data across various parameters. This allows healthcare providers to make informed decisions promptly. Whether in a hospital, clinic, or emergency setting, this monitor reliably supports continuous patient evaluation and management.
Recommendations
To get the most out of the Bedside Monitor YR02174, regular calibration and software updates are recommended. Ensuring staff is trained on its features and options can maximize its use and efficiency. For purchasing inquiries or to generate an automatic quotation, please consult the Kalstein Plus platform for guidance tailored to your needs.
Features
- 15-inch high-resolution display
- Standard and optional multi-parameter configurations
- Suitable for adult and pediatric patients
- Wall mount and trolley available
- Touch screen option for ease of use
Technical Specifications
Model | YR02174 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | 1.25, 2.5, 5.0, 10, 20, 40mm/mV, Auto. | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 20~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.5MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP
|
Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second. | |
Average Time Constant | <10 Second. |