Description
The Bedside Monitor YR02173 is a state-of-the-art device designed for precise patient monitoring. Featuring a superb 12.1-inch touch screen, it provides clear and detailed readings across a range of parameters, including a 5-lead ECG, respiration rate, temperature, SpO2 levels, and non-invasive blood pressure. With advanced capabilities such as dual-IBP, EtCO2, and Bispectral Index monitoring, this device is perfect for a variety of clinical settings. Its ability to be mounted on a trolley or wall further exemplifies its versatility. Designed for accuracy and ease of use, it ensures healthcare providers can focus more on patient care.
Market Pricing
When it comes to the pricing of bedside monitors, the Bedside Monitor YR02173 falls within a competitive range. Typically, this type of equipment is priced between $2000 and $2800 in the market. The price reflects the sophisticated technology and the broad range of features that cater to comprehensive patient monitoring needs.
Frequently Asked Questions
What type of patients can be monitored with this device? The device is suitable for adult, pediatric, and neonatal patients, ensuring versatility in various healthcare settings.
Is the device portable? Yes, it can be mounted on a trolley or wall, providing ease of portability and installation depending on the clinical need.
Advantages and Disadvantages
Advantages: The large touch screen and comprehensive parameter monitoring make it a user-friendly and complete solution for patient monitoring. Its adaptability with multiple accessories like a trolley and wall mount increases its usability in different environments.
Disadvantages: Its wide range of features and complexity might require some time for new users to learn optimally.
Field Usage
The Bedside Monitor YR02173 is extensively used in hospitals and clinics to ensure continuous patient monitoring. It provides critical parameter readings essential for making informed decisions during patient care. Its reliable performance makes it indispensable in emergency and ICU settings.
Recommendations
It is recommended to conduct regular maintenance checks and calibrations on the device to ensure precise readings. Users should take advantage of the platform’s user manuals and calibration guides to maintain the device in optimal working condition.
Features
- 12.1 inch touch screen
- 5-lead ECG, RESP, Temp (Single Channel), COMEN SpO2, NIBP, HR
- Dual-IBP, EtCO2, AG, ICG, C.O., BIS, Nellcor/Masimo SpO2, 3/12-lead ECG, Thermal Recorder, Dual-Temp, Suntech NIBP, Trolley, Wall mount
Technical Specifications
Model | YR02173 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | 1.25, 2.5, 5.0, 10, 20, 40mm/mV, Auto. | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 15~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.5MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP
|
Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 60~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | About 1 Second. | |
Average Time Constant | <10 Second. |